Fuel Prefilter Element Cleaning
Fuel
Prefilter Element Cleaning - EuroV MBE900
- Open the fuel filler cap to release pressure in the fuel system. Replace and tighten the cap.
- Clean the outside of the prefilter housing. Keep fuel away from hoses or pipes located beneath the filter
- Unscrew the cap on the fuel prefilter. Pull the cap and filter element out of the prefilter housing.
- Clean the cap and the filter element. If the filter element is heavily soiled or damaged, replace it.
- Check the O-ring on the cap and replace it if necessary.
- Insert the filter element into the prefilter housing and screw the cap onto the housing. Tighten the cap 25 N·m (18 lb·ft ).
- To bleed the fuel system, make sure that all high-pressure lines have been tightened to 25 N·m (18 lb·ft) and all banjo bolts to 40 N·m (30 lb·ft).
- If equipped with a hand pump on the fuel/water separator, work the hand pump 50 times.
- Crank the engine for 30 seconds at a time, but no longer. Before cranking the engine again, wait at least two minutes. The engine should start within four 30-second attempts.
Notice: Correct torque on the high pressure lines is critical. Incorrect
torques could result in leaks or lack of power due to restricted fuel
flow.
Note: