Air Restriction Gauge

SD DM 04.03.02

The air intake restriction gauge measures the vacuum on the engine side of the air cleaner. On standard installations, it is mounted on the air intake duct in the engine compartment. As an option for easier viewing, an air intake restriction gauge may be located in the ICU.

Note:  Rain or snow can wet the air filter, causing a temporarily higher than normal reading.

Air intake restriction vacuum is measured in inches of water (inH2O). For vehicles equipped with a graduated indicator (see Fig.) or a restriction gauge on the dash, check the gauge with the engine off. If the air restriction value equals or exceeds the value shown in Table., the air cleaner element needs to be replaced.

Fig. 1, Manual-Reset Air Restriction Indicator with Graduations

Table 1, Air Intake Maximum Restriction Values

Air Intake Maximum Restriction Values (inH2O)

Engine Make

GHG14, GHG17, and GHG21 Engines

Cummins

25

Detroit

18

    Table 1, Air Intake Maximum Restriction Values

    Note:
    Document Number: 0000122754
    Manual Publication Date: 2025-01-23
    Topic Publication Date: 2025-01-23