Air Restriction Gauge
The air intake restriction gauge measures the vacuum on the engine side of the air cleaner. On standard installations, it is mounted on the air intake duct in the engine compartment. As an option for easier viewing, an air intake restriction gauge may be located in the ICU.
Note: Rain or snow can wet the air filter, causing a temporarily higher than normal reading.
Air intake restriction vacuum is measured in inches of water (inH2O). For vehicles equipped with a graduated indicator (see Fig.) or a restriction gauge on the dash, check the gauge with the engine off. If the air restriction value equals or exceeds the value shown in Table., the air cleaner element needs to be replaced.
Table 1, Air Intake Maximum Restriction Values
Air Intake Maximum Restriction Values (inH2O) |
||
Engine Make |
GHG14, GHG17, and GHG21 Engines |
|
Cummins |
25 |
|
Detroit |
18 |