Inspection of the Electric Motor, Electric Vehicle

wv mm 08.02.000

Danger: Electric vehicles are equipped with a high-voltage system. Do not attempt any type of electrical work on the vehicle unless you have completed HV3 Daimler Safety Training. Failure to do so could cause severe personal injury or death.

  1. Park the vehicle on a level surface, shut down the engine, and set the parking brake.
  2. Danger: Do not touch the high-voltage cables. Doing so may result in severe personal injury or death.

  3. Inspect the drive motor supply cables and high voltage power supply cables for chaffing, rubbing, and cracks. do not touch the cables. See Fig..
  4. Note: The drive motor supply cables are bolted inside the motor; they do not plug in.

  5. Inspect the drive motor supply cables where they connect to the motor and ensure that they are properly connected; do not touch the cables. See Fig..
    1. Drive Motor Supply High Voltage Cables

    2. High Voltage Power Supply Cables

    Fig. 1, High Voltage Cables

Note:
Document Number: 0000116484
Manual Publication Date: 2024-05-14
Topic Publication Date: 2024-11-19