Checking and Cleaning the Ground Cables

sb mm 54.01.001

Check that the ground cables are clean, undamaged, and tight. If necessary, disconnect them and clean the mating surfaces with a soda solution. Then, connect them securely. Spray the ground cable connections with dielectric red enamel. See Table. for approved protectants.

Table 1, Approved Dielectric Protectants

Approved Dielectric Protectants

Protectant Material

Approved Brand

Dielectric Grease

Lubriplate FLP DS–ES

Dielectric Red Enamel Spray-On Application

3M 1602 IVI-Spray Sealer; order from the PDC

Spray-On B–6–665

Dielectric Red Enamel Brush-On Application

Glyptal 1201EW-Low VOC, Red; order at www.glyptal.com or 1-800-GLP-1201

    Table 1, Approved Dielectric Protectants

    Note: