Bendix Automatic Drain Valve Operating and Leakage Tests
Operating Test
Perform the following test after repairing or replacing the DV-2 valve, to ensure that the valve is functioning properly.
With the system charged, apply the brakes several times. Each time the brakes are applied, an exhaust of air should occur from the exhaust port of the drain valve. If no air comes out, push the wire stem located inside the exhaust port. If no air comes out after pushing the wire stem, there may be a plugged filter in the adapter which should be replaced.
If the drain valve does not function properly, repair or replace it. See Chassis Plumbing Diagram of the Shuttle Bus Chassis Workshop Manual .
Leakage Test
Perform the following test after repairing or replacing the DV-2 valve, to ensure that the valve is functioning properly.
With the system charged and pressure stabilized in the system, there should be no leaks at the drain valve exhaust port. A constant slight exhaust of air at the drain valve exhaust port could be caused by excessive leakage in the air brake system.
If the drain valve is leaking excessively, repair or replace it. See Chassis Plumbing Diagram of the Shuttle Bus Chassis Workshop Manual .