Removal of the Water Coalescer/Final Filter - Two-Filter System
Removal of the Water Coalescer/Final Filter
- 2-Filter System - Ops
Remove the water coalescer/final filter as follows:
Notice: Do not tilt the
water
coalescer/final filter when removing it from the housing. Possible
damage to the water coalescer/final filter or stand pipe may occur.
- Using a 36mm socket, unscrew the water coalescer/final filter cap.
- Pull the cap and water coalescer/final filter straight up and allow the fuel to drain back.
- Remove the water coalescer/final filter (2) from the water coalescer/final filter cap (1) by placing the filter on a solid surface with the drain back plug location at 12 o’clock (3) and apply pressure on the water coalescer/final filter cap at an angle.
- Discard the water coalescer/final filter.
- Inspect inside the housing for any large debris, clean housing as needed.
- Discard water coalescer/final filter cap seal ring.
Note: