AMGaDS III Plus Control Module and Alarm Panel

m2 dm 16.03.004

The AMGaDS III Plus gas detection system driver interface is located on the overhead console, and consists of an alarm panel on the right side and the control module on the left side.

The alarm panel has a green light, a red light, a buzzer, and a sensor. See Fig.. It is located within view from outside of the vehicle. The large green light is continuously illuminated during normal operating conditions.

Before entering the vehicle, always verify that the green light is illuminated. If the green light is not illuminated, do not enter the vehicle. Complete the alarm procedure previously outlined.

The alarm panel meets the California Highway Patrol Title 13-2008 and NFPA 52 2010 requirements. All drivers and technicians using it should be trained regarding the red and green lights, and the audible warning.

  1. Test Button

  2. Sensor Fault Indicator Lights

  3. Zone 1 Leak Indicator Lights

  4. Power Indicator Light

  5. Zone 2 Leak Indicator Lights

  6. Silence Button

  7. Silenced Engaged Light

  8. Relay Engaged Light

  9. Shutdown Reset Button

  10. Buzzer Alarm

  11. Red Light

  12. Green Light

  13. Sensor

Fig. 1, AMGaDS III Plus Control Module and Alarm Panel

The control module, located on the left side of the overhead console, contains the status lights and control buttons for the system. The areas that the sensors monitor are defined as Zone 1 (cab) and Zone 2 (engine compartment). The control module has lights assigned to each zone that will illuminate if a sensor detects a trace level leak (between 20% and 30% LFL), a significant level leak (above 50% LFL), or if a sensor is disconnected or malfunctioning.

  • Trace Level: If either sensor detects gas fumes at a concentration greater than 20% to 30% LFL (1% gas in air by volume), the amber light next to the "Trace" indicator for that zone will flash. There is no buzzer alarm for a trace level detection, and the large green light on the alarm panel will remain illuminated.

  • Significant Level: If either sensor detects gas fumes at a concentration greater than 50% to 60% LFL (2.5% gas in air by volume), the small red light next to the "SIGNIFICANT" indicator for that zone will flash. After approximately 15 seconds, the large green light on the alarm panel will switch off, the red light will illuminate, and the buzzer will sound. All alarm indicators will remain on as long as fumes are detected.

  • Sensor Fault: If the system detects that either of the sensors has been disconnected or has malfunctioned, an amber light next to the "Sensor Fault" indicator for that zone will illuminate.

The control module also has buttons used to test or reset the control module after an alarm. Red lights next to each button indicate when they are engaged.

  • Shutdown Reset: If an alarm has been activated and the "Relay Engaged" light is illuminated, the "Shutdown Reset" button will reset the internal relay. Press the "Shutdown Reset" button only after the gas has cleared, the buzzer has turned off, and the alarm panel light has returned to green.

  • Push To Silence: If an alarm has been activated, the "Push To Silence" button will silence the buzzer.

See Table. for the functions of all lights and buttons on the overhead console.

Table 1, AMGaDS III Plus Control Module Functions

AMGaDS III Plus Control Module Functions

Item

Display

Function

Action Required

Green Power Light

Illuminated

System is on.

None required.

Unlit

Detection system is not functioning.

Ensure the batteries are connected and replace any blown fuses. If the gas detection system is still not functioning, replace the system immediately.

SIGNIFICANT Gas Concentration Lights

Red (illuminated)

Dangerous gas concentration detected.

Suspend vehicle operation immediately and follow alarm procedures.

Trace Gas Concentration Lights

Amber (flashing)

Minor gas concentration detected.

Use caution and monitor the system.

Sensor Fault Lights

Off

Sensor is functioning properly.

None required.

On

Sensor has malfunctioned.

Replace the sensor immediately.

Shutdown Reset Button

Resets the system after an alarm activation.

Press to reset the system only after the gas has cleared, the buzzer has turned off, and the alarm panel light has returned to green.

Relay Engaged Light

On

Relay is engaged and test or alarm is being cleared.

Press the Shutdown Reset button.

Off

Normal condition.

None required.

Test Button

Tests the control module operation and circuitry.

Press and hold for one minute to activate a test of all control module components.

Silence Button

Silences the alarm buzzer.

Press to silence the alarm buzzer.

Silence Engaged Light

On

Indicates the buzzer is active but silenced.

Suspend vehicle operation immediately and follow alarm procedures.

Off

Normal condition.

None required.

    Table 1, AMGaDS III Plus Control Module Functions

    Note:
    Document Number: 0000118174
    Manual Publication Date: 2025-02-11
    Topic Publication Date: 2024-05-09