Failure Display Mode/Fault Codes
The VS-400 performs internal diagnostics at power-up, then continuously monitors system components thereafter.
If a failure is detected, depending on what features are affected, the DIU displays a screen similar, see Fig., blinks the orange fault light, and sounds a tone. Press the OK button to acknowledge the fault.
After the fault has been acknowledged by the driver pressing the OK button, the DIU will attempt to return to normal operations. The orange LED is continuously illuminated while the fault persists. If the fault disappears, the VS-400 transmits a message to indicate that the fault status has changed to a previously active fault.
In the event the FLR antennae becomes blocked while the vehicle is moving (e.g., snow, mud, ice, tampering, etc.), the system sounds a tone and displays the fault screen, see Fig..
Previously active fault codes can be reviewed, tested, and cleared using the Eaton Service Ranger diagnostic tool. Contact an authorized Freightliner dealer to review and clear previously active fault codes. See Fig. for common fault codes.
Table 1, VORAD Fault Codes
VORAD Fault Codes |
||||
Device |
SPN |
FMI |
Description |
Notes |
DIU/FLR |
639 |
2 |
One or more required messages missing from datalink |
— |
DIU/FLR |
639 |
9 |
No message being received from datalink |
— |
DIU/FLR |
639 |
13 |
Device cannot claim source address on datalink |
— |
DIU/FLR |
639 |
19 |
Messages received with incorrect data or marked as error |
— |
FLR |
886 |
7 |
FLR misaligned |
— |
FLR |
886 |
12 |
FLR internally defective |
— |
FLR |
886 |
13 |
FLR not configured properly |
— |
FLR |
886 |
14 |
FLR blocked |
— |
DIU |
893 |
12 |
DIU internally defective |
— |
FLR |
898 |
13 |
Engine not configured for SmartCruise operation |
Tested only if SC configured |
FLR |
898 |
14 |
Engine not supported for SmartCruise operation |
Tested only if SC configured |
DIU/FLR |
1563 |
13 |
VS-400 component detects incompatibility issue with other VS-400 devices |
— |
DIU |
1703 |
3 |
External right speaker shorted high |
Tested only if external right speaker configured |
DIU |
1703 |
4 |
External right speaker shorted low |
Tested only if external right speaker configured |
DIU |
1703 |
5 |
External right speaker open |
Tested only if external right speaker configured |
DIU |
1704 |
3 |
External left speaker shorted high |
Tested only if external left speaker configured |
DIU |
1704 |
4 |
External left speaker shorted low |
Tested only if external left speaker configured |
DIU |
1704 |
5 |
External left speaker open |
Tested only if external left speaker configured |