Inverter/Charger

4700 dm 09.04.000

The optional Freedom HF Inverter/Charger powers small appliances and other electric equipment. It is located in the driver-side luggage compartment. See Fig.. The unit has one three-pin GFIC OUT connector, one three-pin GFIC IN connector, and two AC power outlets.

There are two models available for the Western Star:

  • 1000W : 1000 watt, 20-amp

  • 1500W : 1500 watt, 40-amp

Fig. 1, Inverter/Charger

Danger: Do not store gasoline, flammable material, or any component with a connection to the fuel system in the storage compartment with the inverter/charger. The unit contains equipment that may produce sparks. Storing flammable or electrical equipment in proximity to the unit could result in fire or explosion hazards, which could result in serious injury or death.

The display on the sleeper control panel provides information about the operation of the unit. See Fig.. See Table. for details on the display panel.

  1. Power

  2. LED Display

  3. Select

  4. Input Voltage LED

  5. Input Current LED

  6. Output Power LED

  7. Status LED

Fig. 2, Inverter/Charger Display Panel (1000W shown)

Table 1, Display Panel Functions

Display Panel Functions

Number

Name

Function

1

Power

Press the power button for one second to turn on the unit.

Press and hold the button for five seconds to enter the feature settings mode, then press the button to toggle between the following modes:

  • Charging Current Setting

  • Inverter Mode Setting

  • Alarm Setting

  • Shutdown Setting

  • Factory Setting

Refer to the owner's manual for more information.

2

LED Display

The LED display screen shows status information and fault codes.

3

Select

The Select button changes the display or settings.

Press the Select button to cycle through the setting options. Press and hold the Select button for five seconds to save the setting. Refer to the owner's manual for more information.

  • In "Inverter Mode Setting" press the button to turn the inverter mode ON or OFF.

  • With the inverter mode ON, press the button to choose what appears on the LED display screen: Input Voltage, Input Current, or Output Power. Details are provided below.

    Note: The unit is in "Inverter Mode" when shore power is not present and the unit is using the battery to power the appliances connected to it.

  • In an alarm condition, press and hold the button for two seconds to disable or enable the audible alarm.

  • In "Charging Current Setting" mode, press the button to select the charger current.

4

Input Voltage LED

In inverter mode, when Input Voltage is selected, the corresponding LED will light up and the display will show the input voltage.

5

Input Current LED

In inverter mode, when Input Current is selected, the corresponding LED will light up and the display will show the input current.

6

Output Power LED

In inverter mode, when Output Power is selected, the corresponding LED will light up and the display will show the output power.

7

Status

The color of the Status light indicates the unit's mode of operation:

  • Green : Utility (Shore Power Mode)

    A solid green light indicates that the battery is fully charged.

    A flashing green light indicates that the unit is charging the battery.

  • Yellow : Battery (Inverter Mode)

    A solid yellow light indicates that the unit is using the battery to supply AC power.

    A flashing yellow light indicates that the unit is in inverter mode, but that AC shore power is detected and is transferring to shore power mode within 20 seconds.

  • Red : Fault Condition

    The fault status light indicates a fault condition with the unit. Refer to the owner's manual for fault code information and troubleshooting procedures.

    Table 1, Display Panel Functions

    For more information about troubleshooting, settings, and other features, refer to the owner's manual included with the inverter/charger.

    Note:
    Document Number: 0000118234
    Manual Publication Date: 2024-05-13