Maintenance Operation Sets Table: 00–08
49X mm 00.08.001
Table 1, Maintenance Operation Sets
- On vehicles equipped with Detroit transmissions, the release bearing does not need to be lubricated. On vehicles equipped with Eaton Fuller UltraShift PLUS transmissions, lubricate the release bearing every 50,000 miles (80 000 km) or three months.
- For Eaton Fuller transmissions, fluid change intervals are extended to 500,000 miles (800 000 km) on vehicles filled with synthetic transmission fluid.
- For Chalmers, Henrickson, and NEWAY products, consult vendor documentation for maintenance schedules and information.
- For Schedule I vehicles with Detroit axles, complete this procedure once a year or every 25,000 miles (40 000 km), whichever comes first.
- If equipped with an oil-coalescing desiccant cartridge, replace the cartridge once a year, regardless of mileage. Otherwise use the M3 maintenance interval.
- The automatic drain valve should be inspected every six months or 1500 operating hours, whichever comes first.
Table 1, Maintenance Operation Sets
Note: