Reactivation of the Freeze Season
cen mm 42.04.000
Maintenance is required during both the freeze season and the off season to keep the alcohol evaporator in good working order.
- Remove the filler cap, and check the cap tetraseal.
- Remove the capscrews and reservoir from the cover.
- Remove the cover tetraseal.
- Drain the air tank, and disconnect the line from the evaporator outlet. Remove the check-valve retainer, spring, and disc.
- Install the disc, spring, and check-valve retainer, and connect the line to the evaporator outlet.
- Install the cover tetraseal.
- Install the reservoir on the cover and tighten the capscrews.
- Fill the reservoir with 40 ounces (1183 mL) of methyl alcohol, then install the filler cap.
Note: