Reactivation of the Freeze Season

cen mm 42.04.000

Maintenance is required during both the freeze season and the off season to keep the alcohol evaporator in good working order.

  1. Remove the filler cap, and check the cap tetraseal.
  2. Remove the capscrews and reservoir from the cover.
  3. Remove the cover tetraseal.
  4. Drain the air tank, and disconnect the line from the evaporator outlet. Remove the check-valve retainer, spring, and disc.
  5. Install the disc, spring, and check-valve retainer, and connect the line to the evaporator outlet.
  6. Install the cover tetraseal.
  7. Install the reservoir on the cover and tighten the capscrews.
  8. Fill the reservoir with 40 ounces (1183 mL) of methyl alcohol, then install the filler cap.
Note: