Replacement of the Sleeper Air Filter, Water-Valve Controlled
cen mm 83.02.000
Replace the air filter in the sleeper HVAC unit every six months, regardless of mileage. The filter should not be cleaned.
Caution: If the sleeper air filter is not replaced every six months, damage to the heater and air conditioner components could occur. The HVAC system should not be operated without the recirculation air filter installed.
- Turn off the engine, apply the brakes, and chock the tires.
- Access the sleeper HVAC housing by raising the mattress and bunk panel to the locked position. If there is a baggage compartment, the sleeper HVAC assembly may be accessed through the baggage door on the right side of the vehicle.
- Slide the screen off the sleeper HVAC assembly. See Fig..
- Lift the filter out of the sleeper HVAC assembly and discard the filter.
- Place a new filter in the sleeper HVAC assembly.
- Slide the screen into the frame on the sleeper HVAC assembly.
- Lower the bunk panel and mattress.
- Remove the chocks from the tires.
Note: